Technics - DV250 - Cassette Deck
LINDOS AUDIO SEQUENCE TEST Technics - DV250 - Cassette Deck
SOURCE MS10 V3.0 Vol -14dB, EQ Super-Sound, AL=-6dB
07-Feb-06 09:09 PM


FREQUENCY RESPONSE @-10dB [v]
20Hz -8.75 -7.38
31Hz -3.62 -3.13
40Hz -0.62 +0.00
50Hz -1.62 -1.13
100Hz +0.63 +1.63
315Hz +0.87 +1.13
1k0 0.00 +0.00
6k3 -1.00 -2.24
10k0 -2.12 -2.99
12k5 -3.25 -4.13
14k0 -4.37 -5.38
16k0 -5.25 -6.88
20k0 -10.87 -13.13
25k0 -21.25 -21.63
TEST LEVEL OUT 400Hz [t]
TL dB 01.61 02.41
DELms
SPEED ERROR [e]
SPD+% 00.61
NOISE ITU-468 Q-Pk REL [m]
WTD -34.40 -34.58
DIST RES 1kHz WTD REL [r]/q
-20dB -15.98 -15.57
0dB -31.03 -31.07
+8dB -28.76 -27.94
PHASE R-L [z]
3k15 -04.00
10k0 30.00
15k0 -06.00


Volume control on unit shown in dB, with 0dB as the maximum.

Volume needed to be set at -14dB to get the test level as close as possible to 0dB on the MS10.

'Super-Sound Equaliser' is a preset that gives the most realistic sound according to the manual.

Tape deck 1 tested with NR=OFF side of tape and NR=OFF on unit

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

LA100 Testimonial

"If someone is looking for an accurate, reliable, economical, easy to use test system for audio quality test, Lindos is the answer for it.We have been using many of this unit (LA100) in our broadcast TV and FM Radio maintenance works and will continue using is for many years.

It is surely the best test gear for line, transmitter, amplifiers and other audio related equipment tests.We consider it a must have unit for out broadcast TV and FM Radio maintenance team."

Baithori Kamdi,
Broadcast Engineer,
Telecom Malaysia

LA100 Application Notes

Looking for information about the LA100?

The LA100 Application Notes page contains many downloadable documents. These cover a wide variety of topics including upgrading, optimising and operating the unit.

LA100 Application Notes