Marantz - CD-48 - CD Player
LINDOS AUDIO SEQUENCE TEST Marantz - CD-48 - CD Player
SOURCE MS20 V1.1
18-May-07 12:37 PM TOLERANCE Lindos GradeA FAILED


FREQUENCY RESPONSE @0dB [u]
20Hz -0.50 -0.50 ±2
31Hz -0.12 -0.25 ±1
40Hz -0.12 -0.13 ±1
50Hz -0.12 -0.13 ±1
100Hz 0.00 -0.01 ±1
315Hz 0.00 -0.01 ±1
1k0 0.00 -0.01 ±1
6k3 -0.12 -0.13 ±1
10k0 -0.12 -0.13 ±1
12k5 -0.12 -0.13 ±1
14k0 -0.25 -0.25 ±1
16k0 -0.25 -0.25 ±1
20k0 -0.37 -0.38 ±2
25k0 -12.25 -12.38
LEVEL VS LEVEL [h]
TEST LEVEL OUT 1kHz [t]
TL dB -03.86* -03.78* ±1<1
DELms <100
NOISE ITU-468 Q-Pk REL [n]
WTD -66.55 -65.73 -60
DIST RES 1kHz WTD REL [r]/q
-20dB -45.71 -45.58 -40
0dB -63.96 -64.14 -45
+8dB -69.56 -69.69 -45
+12dB -71.01 -70.86 -45
+15dB -71.14 -71.03 -45
+18dB -68.09 -67.48 -45
PHASE DIFFERENCE R-L [z]
3k15 00.00 ±10
10k0 -04.00 ±20
15k0 04.00 ±30


Tested using SEQ3 and segment 'h' from Lindos test CD2.

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

LA100 Application Notes

Looking for information about the LA100?

The LA100 Application Notes page contains many downloadable documents. These cover a wide variety of topics including upgrading, optimising and operating the unit.

LA100 Application Notes

LA100 Testimonial

"If someone is looking for an accurate, reliable, economical, easy to use test system for audio quality test, Lindos is the answer for it.We have been using many of this unit (LA100) in our broadcast TV and FM Radio maintenance works and will continue using is for many years.

It is surely the best test gear for line, transmitter, amplifiers and other audio related equipment tests.We consider it a must have unit for out broadcast TV and FM Radio maintenance team."

Baithori Kamdi,
Broadcast Engineer,
Telecom Malaysia