Marantz - CD-48 - CD Player
LINDOS AUDIO SEQUENCE TEST Marantz - CD-48 - CD Player
SOURCE MS20 V1.1
18-May-07 12:37 PM TOLERANCE Lindos GradeA FAILED


FREQUENCY RESPONSE @0dB [u]
20Hz -0.50 -0.50 ±2
31Hz -0.12 -0.25 ±1
40Hz -0.12 -0.13 ±1
50Hz -0.12 -0.13 ±1
100Hz 0.00 -0.01 ±1
315Hz 0.00 -0.01 ±1
1k0 0.00 -0.01 ±1
6k3 -0.12 -0.13 ±1
10k0 -0.12 -0.13 ±1
12k5 -0.12 -0.13 ±1
14k0 -0.25 -0.25 ±1
16k0 -0.25 -0.25 ±1
20k0 -0.37 -0.38 ±2
25k0 -12.25 -12.38
LEVEL VS LEVEL [h]
TEST LEVEL OUT 1kHz [t]
TL dB -03.86* -03.78* ±1<1
DELms <100
NOISE ITU-468 Q-Pk REL [n]
WTD -66.55 -65.73 -60
DIST RES 1kHz WTD REL [r]/q
-20dB -45.71 -45.58 -40
0dB -63.96 -64.14 -45
+8dB -69.56 -69.69 -45
+12dB -71.01 -70.86 -45
+15dB -71.14 -71.03 -45
+18dB -68.09 -67.48 -45
PHASE DIFFERENCE R-L [z]
3k15 00.00 ±10
10k0 -04.00 ±20
15k0 04.00 ±30


Tested using SEQ3 and segment 'h' from Lindos test CD2.