Western Digital - Media Player TV Live
LINDOS AUDIO SEQUENCE TEST Western Digital - Media Player TV Live
SOURCE MS20 V1.2 Lindos WAV File test
30-Oct-10 03:11 PM TOLERANCE Lindos GradeA FAILED


FREQUENCY RESPONSE @0dB [u]
20Hz -0.87 -0.87 ±2
31Hz -0.37 -0.37 ±1
40Hz -0.12 -0.12 ±1
50Hz -0.12 -0.12 ±1
100Hz -0.12 -0.12 ±1
315Hz 0.00 0.00 ±1
1k0 0.00 0.00 ±1
6k3 -0.12 -0.12 ±1
10k0 -0.12 -0.12 ±1
12k5 -0.25 -0.25 ±1
14k0 -0.25 -0.25 ±1
16k0 -0.25 -0.37 ±1
20k0 -0.50 -0.50 ±2
25k0 -16.75 -17.25
TEST LEVEL OUT 1kHz [t]
TL dB -07.72* -07.65* ±1<1
DELms <100
NOISE ITU-468 Q-Pk REL [n]
WTD -67.04 -67.52 -60
DIST RES 1kHz WTD REL [r]/q
-20dB -45.07 -46.08 -40
0dB -64.48 -65.07 -45
+8dB -70.66 -70.78 -45
+12dB -72.51 -72.68 -45
+15dB -71.76 -70.69 -45
+18dB -39.26* -39.17* -45
PHASE DIFFERENCE R-L [z]
3k15 -26.00* ±10
10k0 -80.00* ±20
15k0 -112.00* ±30


Excellent. I wish I could find a compact D-A converter for PC use with this level of performance!

Frequency response is excellent and noise is almost as good as it gets for a 16bit noise-shaped recording - within 1dB of the very best high end converters! No audible artifacts on high freqeuncy tones.

Links
Home Page
Latest News

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

LA100 Testimonial

"If someone is looking for an accurate, reliable, economical, easy to use test system for audio quality test, Lindos is the answer for it.We have been using many of this unit (LA100) in our broadcast TV and FM Radio maintenance works and will continue using is for many years.

It is surely the best test gear for line, transmitter, amplifiers and other audio related equipment tests.We consider it a must have unit for out broadcast TV and FM Radio maintenance team."

Baithori Kamdi,
Broadcast Engineer,
Telecom Malaysia

LA100 Application Notes

Looking for information about the LA100?

The LA100 Application Notes page contains many downloadable documents. These cover a wide variety of topics including upgrading, optimising and operating the unit.

LA100 Application Notes