Canon - EOS 5D - Video
LINDOS AUDIO SEQUENCE TEST Canon - EOS 5D - Video
SOURCE MS20 V1.3 Record level - one step up from bottom.
24-Mar-11 03:47 PM


FREQUENCY RESPONSE @0dB [u]
20Hz -18.00 -18.12
31Hz -12.75 -12.87
40Hz -10.75 -10.75
50Hz -8.50 -8.50
100Hz -4.00 -4.12
315Hz -0.50 -0.37
1k0 0.00 +0.12
6k3 +0.12 +0.25
10k0 +0.25 +0.37
12k5 +0.25 +0.37
14k0 0.00 +0.25
16k0 -0.12 0.00
20k0 -12.75 -12.62
25k0 -22.00 -22.00
LEVEL VS LEVEL [h]
TEST LEVEL OUT 1kHz [t]
TL dB 00.07 00.21
DELms
NOISE ITU-468 Q-Pk REL [n]
WTD -41.26 -41.26
DIST RES 1kHz WTD REL [r]/q
-20dB -21.59 -25.30
0dB -41.31 -45.44
+8dB -49.39 -53.25
+12dB -53.24 -57.30
+15dB -55.94 -59.29
+18dB -57.32 -60.26
PHASE DIFFERENCE R-L [z]
3k15 28.00
10k0 90.00
15k0 126.00


Input level: -30dBu
With the record level set one step up from the bottom this camera can actually handle professional levels in (+18dBu - single-ended i.e. +12). Poor bass response as is common across consumer/semi-pro cameras and camcorders. Phase error is puzzling, want to retest to confirm.

Note that the noise reading on the distortion plot is incorrect - for complicated reasons.

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

MS10 Upgrades

Any MS10 can be upgraded to an MS20 simply by fitting a new MS20 front panel.

About The MS20
Upgrading Your MS10

LA100 Application Notes

Looking for information about the LA100?

The LA100 Application Notes page contains many downloadable documents. These cover a wide variety of topics including upgrading, optimising and operating the unit.

LA100 Application Notes