Canon - EOS 5D - Video
LINDOS AUDIO SEQUENCE TEST Canon - EOS 5D - Video
SOURCE MS20 V1.3 Record level - one step up from bottom.
24-Mar-11 03:47 PM


FREQUENCY RESPONSE @0dB [u]
20Hz -18.00 -18.12
31Hz -12.75 -12.87
40Hz -10.75 -10.75
50Hz -8.50 -8.50
100Hz -4.00 -4.12
315Hz -0.50 -0.37
1k0 0.00 +0.12
6k3 +0.12 +0.25
10k0 +0.25 +0.37
12k5 +0.25 +0.37
14k0 0.00 +0.25
16k0 -0.12 0.00
20k0 -12.75 -12.62
25k0 -22.00 -22.00
LEVEL VS LEVEL [h]
TEST LEVEL OUT 1kHz [t]
TL dB 00.07 00.21
DELms
NOISE ITU-468 Q-Pk REL [n]
WTD -41.26 -41.26
DIST RES 1kHz WTD REL [r]/q
-20dB -21.59 -25.30
0dB -41.31 -45.44
+8dB -49.39 -53.25
+12dB -53.24 -57.30
+15dB -55.94 -59.29
+18dB -57.32 -60.26
PHASE DIFFERENCE R-L [z]
3k15 28.00
10k0 90.00
15k0 126.00


Input level: -30dBu
With the record level set one step up from the bottom this camera can actually handle professional levels in (+18dBu - single-ended i.e. +12). Poor bass response as is common across consumer/semi-pro cameras and camcorders. Phase error is puzzling, want to retest to confirm.

Note that the noise reading on the distortion plot is incorrect - for complicated reasons.

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

MS10 Upgrade Testimonial

"A very worthwhile upgrade which makes the unit much easier to operate.
Great display!"
Chris Thorpe, CTP Systems

LA100 Application Notes

Looking for information about the LA100?

The LA100 Application Notes page contains many downloadable documents. These cover a wide variety of topics including upgrading, optimising and operating the unit.

LA100 Application Notes