PANASONIC LUMIX - GH2 DSLR with Lindos VA-GH2
LINDOS AUDIO SEQUENCE TEST PANASONIC LUMIX - GH2 DSLR with Lindos VA-GH2
SOURCE MS20 V1.3 Gain 1 and 0dBu alignment level in
23-May-11 02:49 PM TOLERANCE Lindos GradeB FAILED


FREQUENCY RESPONSE @0dB [u]
20Hz -1.62 -1.50 +3-6
31Hz -0.62 -0.50 ±3
40Hz -0.25 -0.25 ±2
50Hz -0.12 0.00 ±2
100Hz 0.00 0.00 ±2
315Hz 0.00 0.00 ±2
1k0 0.00 0.00 ±2
6k3 -0.25 -0.12 ±2
10k0 -0.50 -0.50 ±2
12k5 -0.75 -0.62 ±2
14k0 -0.75 -0.62 ±3
16k0 -0.87 -0.75
20k0 -22.00 -22.00
25k0 -22.00 -22.00
LEVEL VS LEVEL [h]
TEST LEVEL OUT 400Hz [t]
TL dB -04.64* -04.59* ±1.5<1
DELms <100
SPEED ERROR [e]
SPD+% 00.05 ±1
NOISE ITU-468 Q-Pk REL [m]
WTD -49.60* -49.56* -50
DIST RES 1kHz WTD REL [r]/q
-20dB -29.55 -29.13 -25
0dB -48.37 -48.31 -30
+8dB -49.58 -49.51 -30
+12dB -51.31 -51.60 -30
+15dB -50.97 -51.92 -30
+18dB -51.25 -51.31
PHASE DIFFERENCE R-L [z]
3k15 00.00 ±45
10k0 -02.00 ±90
15k0 00.00


Excellent frequency response, noise not bad, but took a lot of effort to eliminate RF effects from the camera ground, and radiated RF, which were causing buzz. This camera uses a 2.5mm jack - do not use made-up leads with conductive plastic outer as they are not effective against the high-frequency processor noise radiated. Gain is extremely high, even on level setting 1, and avc cannot be turned off. This adapter sets a level low enough to avoid avc effects below +8dB AL, above which it can be seen to operate. Distortion is still low up to +18dB AL.

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

Li-ion Battery Upgrades

Lindos now offers Lithium battery upgrades to replace the original Nickel Cadmium battery packs supplied with older units.

Li-ion Upgrade Information

LA100 Application Notes

Looking for information about the LA100?

The LA100 Application Notes page contains many downloadable documents. These cover a wide variety of topics including upgrading, optimising and operating the unit.

LA100 Application Notes