ZOOM H2 - 2-Ch Flash Recorder - Microphone
LINDOS AUDIO SEQUENCE TEST ZOOM H2 - 2-Ch Flash Recorder - Microphone
SOURCE MS20 V1.3 Internal Microphone test - Lindos Studio
15-Aug-11 10:27 AM


FREQUENCY RESPONSE @0dB 20 SEC [s]
20Hz -7.12 -0.88
31Hz -8.50 -1.13
40Hz -8.87 -0.99
50Hz -4.12 +0.63
100Hz -5.37 -1.24
315Hz +1.75 +1.88
1k0 0.00 +0.01
6k3 +3.12 +5.13
10k0 -6.12 -1.13
12k5 -6.87 +0.01
14k0 -6.87 +0.01
16k0 -6.50 +1.01
20k0 -7.75 -0.99
25k0 -8.87 -1.49


Right channel mic is pointed at source to get on-axis response (red). Left channel shows off-axis response.

Low-frequency response is remarkably good for directional mics. The peak at 7kHz spoils the response and is typical of the sort of resonance that creates high-end harshness. Separation is poor, and almost non-existant in the mid to 8k range.

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!


LA100 Silver Upgrades

The LA100 silver upgrade is available to all units whatever the vintage. It adds all of the features in the latest LA100 MK3 to an older unit

Upgrading Your LA100

LA100 Testimonial

"If someone is looking for an accurate, reliable, economical, easy to use test system for audio quality test, Lindos is the answer for it.We have been using many of this unit (LA100) in our broadcast TV and FM Radio maintenance works and will continue using is for many years.

It is surely the best test gear for line, transmitter, amplifiers and other audio related equipment tests.We consider it a must have unit for out broadcast TV and FM Radio maintenance team."

Baithori Kamdi,
Broadcast Engineer,
Telecom Malaysia