YellowTEC - PUC2 - PC Sound Card
LINDOS AUDIO SEQUENCE TEST YellowTEC - PUC2 - PC Sound Card
SOURCE DS10 Tested using DigiSonic
20-Feb-12 03:30 PM


FREQUENCY RESPONSE @0dB [u]
20Hz -1.15 -1.15
31Hz -0.26 -0.26
40Hz -0.18 -0.18
50Hz -0.14 -0.14
100Hz -0.07 -0.06
315Hz -0.01 -0.01
1k0 0.00 0.00
3k1 -0.01 -0.01
6k3 0.00 0.00
10k0 0.00 0.00
12k5 +0.01 +0.01
16k0 +0.04 +0.04
20k0 -0.49 -0.48
PHASE DIFF R-L [z]
20Hz 0.00
31Hz 0.00
40Hz 0.00
50Hz 0.00
100Hz 0.00
315Hz 0.00
1k0 0.00
3k1 0.00
6k3 0.00
10k0 0.00
12k5 0.00
16k0 0.00
20k0 -1.00
TEST LEVEL OUT 1 kHz [t]
TL dB 00.09 00.01
NOISE ITU-468 Q-Pk REL [n]
WTD -102.94 -90.51
DIST RES 1kHz WTD REL [q]/r
-20dB -42.30 -42.27
0dB -62.01 -61.79
+8dB -67.31 -67.34
+12dB -68.20 -68.10
+15dB -67.73 -67.73
+18dB -66.90 -66.90
NOISE VS TIME 20 SEC [l]
ITU-468 Wtd Q-Pk
Peak -73.59
Mean -92.60
SWEPT THD @0dB [d]
20Hz -48.26 -48.33
32Hz -39.71 -39.78
50Hz -39.15 -39.23
63Hz -42.71 -42.79
100Hz -60.91 -60.99
200Hz -70.70 -70.75
315Hz -71.87 -71.88
500Hz -72.15 -72.16
630Hz -72.18 -72.14
1k0 -72.24 -72.21
2k0 -72.32 -72.31
3k15 -72.54 -72.48
5k -72.65 -72.63
10k -72.74 -72.72
LEVEL VS LEVEL [h]
0dB +0.07 -0.01
+1dB +1.08 +1.01
+2dB +2.08 +2.01
+3dB +3.07 +3.00
+4dB +4.08 +4.01
+5dB +5.08 +5.00
+6dB +6.08 +6.01
+7dB +7.08 +7.00
+8dB +8.07 +8.00
+9dB +9.08 +9.01
+10dB +10.07 +10.00
+11dB +11.08 +11.01
+12dB +12.08 +12.01
+13dB +13.07 +13.00
+14dB +14.08 +14.00
+15dB +15.08 +15.00
+16dB +16.09 +16.01
+17dB +17.07 +17.00
+18dB +17.83 +17.81


DigiSonic uses a 16 bit interface to talk to the sound card. Therefore noise results are not correct. i.e. figures below -70 are not correct.

Links
Home Page
Latest News

Like Lindos / Share

MiniSonic Mic Kit

Lindos has launched a new range of microphones and accessories - bringing clarity and presicion to your music and video recordings.

Find out more!

MS20 Testimonial

"In short, I love it. Extremely useful; wonderfully succinct -- I've been looking for a tool like this for 20 years."

Phillip Sztenderowicz,
Technical Department,
Sterling Sound


Latest Article

Lindos proposes UniSon standard to standardise analogue levels for ease of interworking between professional and consumer equipment.

Read about UniSon
Read more articles