SOURCE MS20 V1.3 Wideband and Headroom
06-Aug-19 05:36 PM


FREQUENCY RESP 40-40kHz @0dB [w]
1k0 +0.01 +0.01
20k0 +1.13 +0.50
25k5 +0.38 -0.88
31k5 -3.49 -5.38
40k0 -13.74 -15.63
LEVEL VS LEVEL [h]
TEST LEVEL OUT 400Hz [t]
TL dB 00.21 00.23
DELms 0090
SPEED ERROR [e]
SPD+% -00.07
NOISE ITU-468 Q-Pk REL [m]
WTD -51.34 -51.86


Note the gradual rolloff to 40kHz and the soft limiting (max level is +18dB)